beautypg.com

4 receive revision id register (rxrevid), 5 receive control register (rxcontrol), Section 5.4 – Texas Instruments TMS320C674X User Manual

Page 88: Section 5.5

background image

EMAC Module Registers

www.ti.com

5.4

Receive Revision ID Register (RXREVID)

The receive revision ID register (RXREVID) is shown in

Figure 42

and described in

Table 41

.

Figure 42. Receive Revision ID Register (RXREVID)

31

0

RXREV

R-4EC0 020Dh

LEGEND: R = Read only; -n = value after reset

Table 41. Receive Revision ID Register (RXREVID) Field Descriptions

Bit

Field

Value

Description

31-0

RXREV

Receive module revision

4EC0 020Dh

Current receive revision value

5.5

Receive Control Register (RXCONTROL)

The receive control register (RXCONTROL) is shown in

Figure 43

and described in

Table 42

.

Figure 43. Receive Control Register (RXCONTROL)

31

16

Reserved

R-0

15

1

0

Reserved

RXEN

R-0

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 42. Receive Control Register (RXCONTROL) Field Descriptions

Bit

Field

Value

Description

31-1

Reserved

0

Reserved

0

RXEN

Receive enable

0

Receive is disabled.

1

Receive is enabled.

88

EMAC/MDIO Module

SPRUFL5B – April 2011

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated