Telenetics OM-AMPS-100 User Manual
Page 33
![background image](/manuals/207905/33/background.png)
Section 3
Specifications
OMEGA Installation, Operation, and Maintenance Manual
33
Switches and LED Indicators
Toggle switches and LED indicators are provided for installation,
configuration, and troubleshooting.
Switch controls: AC power ON-OFF
Battery ON-OFF
LED Indications: LED 1: AC Power/Battery Condition
LED 2: Cellular Connection Status
Power Supply
The switching power supply is designed to operate from a wide
range of AC input voltages and is isolated against voltage
transients.
AC power input:
90 to 277 VAC,
50 to 60 Hz
DC power input:
100 to 150 VDC
Output DC voltage:
13.2 volt DC +/- 5%, full
load
Maximum output current:
2.0 amperes
Power consumption:
Idle: 1.3 Watts
Transmit @ 3 Watts: 16.5
Watts
Primary to secondary insulation:
8,000 volts peak at 60 Hz
Battery charge voltage:
13.8 Volts
Input AC fuse rating:
2 amps Slow Blow, 250V
Primary surge protection:
1500 Watt-seconds
Secondary surge protection:
20 KvA