Tektronix 1705A User Manual
Page 99

Checks and Adjustments
5- 4
1705A Spectrum Monitor
6.
Check Resolution Filter
b. CHECK -- that the marker width 0.6 Divisions down from the top is
3 Divisions,
±1 Division.
e.
CHECK
-- that the marker width 0.6 Divisions down from the top of the
signal is
≤2 minor Divisions.
f.
CHECK
-- that the 10 kHz marker amplitude matches the highest point
of the 300 kHz marker amplitude within 1 minor Division.
7.
Check 70 MHz Gain and Flatness
e.
CHECK
-- for a marker amplitude change of 2 Divisions,
±2 minor
Divisions when switching the leveled sine wave generator Amplitude
Multiplier between .01 and 0.1 (a 20 dB change).
i.
CHECK
-- that the tip of the marker is on the crt center line,
±1 minor
Division (vertically).
8.
Check Video Filter
d. CHECK -- that the baseline noise amplitude drops approximately 50%
when the VIDEO FILTER is ON.
9.
Check Sweep Speed
b. CHECK -- for a solid trace with almost no flicker.
d. CHECK -- for approximately 3 to 4 sweeps per second.
Alternate Method
e.
CHECK
-- for a ramp duration of 20 ms
±10 ms.
h. CHECK -- for a ramp duration of 200 ms
±100 ms.
10.
Check L--Band Linearity
e.
CHECK
-- for 10 frequency markers.
f.
CHECK
-- that each marker is within 1 minor Division of a major
graticule line.
11.
Check L--Band SPAN/DIV and Readout
d. CHECK -- for 1 marker every 5 Divisions,
±1 Division.
i.
CHECK
-- for 1 marker every 5 Divisions,
±1 Division.
o. CHECK -- that the marker is intensified.