COMPONENT NAMES AND FUNCTIONS OF THE F39-E1 INTERFACE UNIT

SEND to HS-485 indicator (Red)

SEND to HS-232C indicator (Yellow)

M8 Connector (RS-485)

9pin D-Sub Connector

(HS-232C)

Communication indicator (Green)

SEND to RS-485 Indicator (Red) Lit when the F39-E1 sends data to the F3S-B via RS-485.

SEND to RS-232C Indicator (Yellow) Lit when the F39-E1 sends data to the PC via RS-232C.

COMMUNICATION Indicator (Green) Flashing during communication between the F3S-B and the F39-E1.

J

HARDWARE CONNECTION

WARNING

Disconnect the outputs of the F3S-B from the load when programming it using the F39-U1E software and with F39-E1 Interface

Unit. Failure to do so may result in serious injury.
Do not connect the F39-E1 to a power supply with a voltage higher than 24 VDC +20 %.
Do not connect the F39-E1 to an AC power supply.

!

Wiring Diagram

PC

See

Note.

-JB1C

Receiver

0 V (Blue 3)

+ 24 V

(Brown 1)

F39--E1

F39

F3S- B

No.1 axis

RS-232C

O

pen

O

utput

1

(G

reen

3)

Op

en

Ou

tp

ut

2

(W

hi

te

1)

RS-485 (B)

(Pink 6)

RS-485 (B) (White 2)

0V

(Blue

7)

0V

(Blue

7)

RS-485 (A)

(Grey 5)

24

VD

C

(Brow

n

2)

24

VD

C

(Brow

n

2)

Wiring Procedure

1. For wiring connections, use the F3S-B

Instruction Manual (enclosed with the product).

2. Connect the Interface Cable (F39-JB1C) to the

Interface Unit (F39-E1).

3. Connect the 4 wires of the Interface Cable to

each appropriate line of the F3S-B.

4. Connect an RS-232C Cable to the PC and to the

Interface Unit.

RS-485 (A) (Black 4)

See

Note.

Emitter

F39--U1E