Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner

Page 5

Tilt (Rotation)

Curvature

Curvature

Electrical Specifications

Operating Voltage

+5VDC + 10%

Current

Operating

85mA (typical), 150mA (max)

Idle

55mA (typical), 70mA (max)

Pwr-On Surge

650mA (typical), 1500mA (max)

Specified operation (

θ) + 20 degrees or less. (Barcode aspect ratio allowing laser to

cover all bars). (Recommended operation at 0 degrees)

h

R

JAN 13: R = 30 mm (1.2" ) or

JAN 8: R= 20 mm (0.8") or

Where: PCS 0.9, h = 35.4
α2 = 10°,β = 0°, θ= 0°

EAN-8: R = 15 mm (0.6”) or

EAN-13: R = 20 mm (0.8”).

Where: PCS 0.9, h = 100 mm,

Pitch=15