Opticon LMD 1135 User Manual
Page 9

Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 5
Tilt (Rotation)
Curvature
Curvature
Electrical Specifications
Operating Voltage
+5VDC + 10%
Current
Operating
85mA (typical), 150mA (max)
Idle
55mA (typical), 70mA (max)
Pwr-On Surge
650mA (typical), 1500mA (max)
Specified operation (
θ) + 20 degrees or less. (Barcode aspect ratio allowing laser to
cover all bars). (Recommended operation at 0 degrees)
h
R
JAN 13: R = 30 mm (1.2" ) or
JAN 8: R= 20 mm (0.8") or
Where: PCS 0.9, h = 35.4
α2 = 10°,β = 0°, θ= 0°
EAN-8: R = 15 mm (0.6”) or
EAN-13: R = 20 mm (0.8”).
Where: PCS 0.9, h = 100 mm,
Pitch=15
°, Skew=0°, Tilt=0°