Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner

Page 40

For example, if a Code 39 label of length 2 characters were scanned in Step 3 then only Code 39 labels

would be checked for a minimum length of 2 characters. If a second label had been read in Step 3

(immediately following the first), then that particular symbology could have been set to different

minimum character length.

In a similar manner, the maximum length for selected codes can be established by using the “Enable

maximum length for selected codes” (HM) command.

14. Creating a Prefix and/or Suffix

Computer

Command

Function

/Description

Bar Code

Command

(ZZ)

START/END

Programming Menu

[[

Z3

Display Settings including

Prefix/Suffix value and length

(expressed in hexidecimal

format)

[!

The Z3 command can be used to instruct the scanner to provide a list of its current software settings

including prefixes and suffixes.

The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a

Suffix) is composed of up to 4 characters. The following steps are used to establish a Prefix that will be

transmitted with the bar code data:

1. Scan Start
2. Scan the bar code representing the symbology to which you wish to add a Prefix
3. Scan the character(s) that will comprise the Prefix. Up to four numeric, alpha or control character(s)

may be used.

4. Scan “STOP” to exit the Programming Mode.

Example

: To add the alpha character “A” as a Prefix and “B” as a

Suffix to UPC-A bar code data:

1. Scan “START/END Programming Mode”

2. Scan N1, representing a Prefix for UPC-A

3. Scan 0A, representing the alpha character “A”

4. Scan N6, representing a Suffix for UPC-A

5. Scan 0B, representing the alpha character “B”

6. Scan “START/END Programming Mode”