E-38

drier or the like and do not dry the Case under direct sunlight. Exposure
to high temperatures or direct sunlight may cause deformation,
discoloration or breakage of the Case and deterioration of the O-ring.
Wipe the inside of the Case with a soft cloth not causing any fibers.
Remove the O-ring, wipe off any salt, sand, dust, etc., and also clean the
O-ring groove and the O-ring contact surface in the same way and then
dry them. When an object with a sharp tip is used to remove the O-ring
from the groove, the O-ring may be damaged and water leakage may be
caused. Always use the accessory pick for O-ring removal.

Q6 : How should I take pictures under water?
A6 : Please observe the following items for shooting under water.

(1) Fix the Case with the accessory hand strap to your wrist.
(2) When you place a finger onto the lens window, the finger will appear in

the photo. Pay attention to the position of your fingers when holding the
Case.

(3) When pressing the shutter lever, hold the Case securely with both hands

and operate the lever quietly to prevent camera shake.

(4) Look through the LCD monitor window on the rear of the Case to confirm

the picture and then press the shutter lever. Please note that the
viewfinder cannot be used, When the LCD monitor is used, the battery is
exhausted earlier. In order to avoid losing shutter chances due to an
exhausted battery, please always replace a battery with a fully charged
battery before each dive.

Q7 : How can I check for water leakage?
A7 : For confirmation, perform the advance test and the final test after loading

the camera. The advance test with immersing the Case without the
camera to the intended use depth to check for water leakage is the most
accurate test, but when this is difficult, it is safer to perform this test even
at a depth of 1 m or in a bathtub. The final test also can be performed in
a bathtub or a bucket.

Q8 : What are the causes for entry of water?
A8 : The main causes for the entry of water are shown below. Please check

them most carefully.

(1) Forgetting to install the O-ring
(2) The O-ring is partly or completely outside the groove.
(3) Damage, deterioration, or deformation of the O-ring
(4) Sand, fibers, hair or other foreign matter on the O-ring
(5) When foreign matter (sand, fiber, hair, etc.) is stuck to the O-ring

grooves or O-ring contact surfaces.