Appendix e. connecting rs-530 to rs-422 – RAD Data comm ASMi-31 User Manual
Page 61
E-1
Appendix E
Connecting RS-530 to
RS-422
Table E-1 Connecting RS-530 to RS-422
Signal Function
RS-449 (RS-422/423)
RS-530
37-pin
Pin
Circuit
DB-25 Female
Standalone & Card
Cage Pin
Circuit
Protective Ground
1
Shield
1
Signal Ground
19
SG
7
AB
DTE Common Return
37
SC
DCE Common Return
20
RC
Transmitted Data
4
22
SD (A)
SD (B)
2
14
BA (A)
BA (B)
Received Data
6
24
RD (A)
RD(B)
3
16
BB (A)
BB (B)
Request to Send
7
25
RS (A)
RS (B)
4
19
CA (A)
CA (B)
Clear to Send
9
27
CS (A)
CS (B)
5
13
CB (A)
CB (B)
Data Set Ready
11
29
DM (A)
DM (B)
6
22
CC (A)
CC (B)
Carrier Detect
13
31
RR (A)
RR (B)
8
10
CF (A)
CF (B)
External Transmit
Clock
17
35
TT (A)
TT (B)
24
11
DA (A)
DA (B)
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com