beautypg.com

RAD Data comm ARC-101 User Manual

Page 44

background image

Chapter 4. Software Management

ARC-101 Installation & Operation Manual

4-10

Performance Monitoring Window

E3 Link Status Window

LOS

Loss of Signal

OOF

Out of Frame

LOC

Loss of Cell Delineation

AIS

Alarm Indication Signal

RDI

Remote Defect Indicator

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the
"Last Sec." column indicates that there are one or more errors in the last second. The number in the "All"
column is equal to the cumulative number of seconds in which errors occurred.

BIP

Bit Interleaved Parity

FEBE

Far End Block Error

E1 Link Status Window

LOC

Loss of Cell Delineation

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the
"Last Sec." column indicates that there are one or more errors in the last second. The number in the "All"
column is equal to the cumulative number of seconds in which errors occurred.

ATM Traffic
Monitoring

ATM cell statistics are displayed in this window - the number of events that
have occurred since counters reset or overflow in the right and left
modules:

Cells transmitted

Cells received

Cells discarded due to HEC errors

ATM STATUS

Left Module

Last Sec.

All

Right Module

Last Sec.

All

Cells
Transmitted:

1200

412000

Cells
Transmitted:

1990

412010

Cells
Received

1208

412020

Cells
Received

1990

412000

Cells
Discarded:

Cells
Discarded:

(HEC errors)

0

0

(HEC errors)

0

0

Time since the last Counters Reset:

00:34:46

Press ESC to exit