Chapter 1. Introduction

Specifications

1-5

Ordering

ARC-101/#
ATM Rate Converter

# Specify power supply:

AC for 90-260 VAC
DC for - 48 VDC

ARC-M/@
Interface module for ARC-101

@ Specify module name - see tables below

RM-1

Hardware for mounting one unit in a 19" rack.

RM-2

Hardware mounting for two units in a 19" rack.

Table 1-1 Optical Module Characteristics

Module

Name

Protocols

Supported

Fiber Type

(Wavelength)

Connector

Type

Dynamic

Range

Optical

Power

(typical)

Sensitivity

SC13M/155

STS-3c

STM-1

62.5/125

(1300 nm)

Duplex SC

16 dB

-18 dBm

-31 dBm

ST13S/155

STS-3c

STM-1

9/125

(1300 nm)

ST (LED)

16 dB

-18 dBm

-31 dBm

ST13L/155

STS-3c

STM-1

9/125

(1300 nm)

ST (LASER)

16 dB

-12 dBm

-31 dBm

Table 1-2 Electrical Module Characteristics

Module

Name

Protocols

Supported

Cable

Type

Connector

Type

Range/Budget

Coding

Method

Impedance

(Ohms)

UTP/155

STS-3c

STM-1

UTP Cat 5

Shielded

RJ-45

100 m

NRZ

100

CX/BNC/155

STS-3c

STM-1

Coax

BNC

12.7 dB*

CMI

75

T3

T3

Coax

BNC

150 m

B3ZS

75

E3

E3

Coax

BNC

150 m

HDB3

75

E1

E1

Coax (UTP)

BNC (RJ-45)

12 dB

HDB3

75 (120)

E1/LTU

E1

Coax (UTP)

BNC (RJ-45)

12 dB

HDB3

75 (120)

* At 78 MHZ, according to the square root of the frequency law.