RAD Data comm ARC-101 User Manual
Page 15
ARC-101 Installation & Operation Manual
Chapter 1. Introduction
Specifications
1-5
Ordering
ARC-101/#
ATM Rate Converter
# Specify power supply:
AC for 90-260 VAC
DC for - 48 VDC
ARC-M/@
Interface module for ARC-101
@ Specify module name - see tables below
RM-1
Hardware for mounting one unit in a 19" rack.
RM-2
Hardware mounting for two units in a 19" rack.
Table 1-1 Optical Module Characteristics
Module
Name
Protocols
Supported
Fiber Type
(Wavelength)
Connector
Type
Dynamic
Range
Optical
Power
(typical)
Sensitivity
SC13M/155
STS-3c
STM-1
62.5/125
(1300 nm)
Duplex SC
16 dB
-18 dBm
-31 dBm
ST13S/155
STS-3c
STM-1
9/125
(1300 nm)
ST (LED)
16 dB
-18 dBm
-31 dBm
ST13L/155
STS-3c
STM-1
9/125
(1300 nm)
ST (LASER)
16 dB
-12 dBm
-31 dBm
Table 1-2 Electrical Module Characteristics
Module
Name
Protocols
Supported
Cable
Type
Connector
Type
Range/Budget
Coding
Method
Impedance
(Ohms)
UTP/155
STS-3c
STM-1
UTP Cat 5
Shielded
RJ-45
100 m
NRZ
100
CX/BNC/155
STS-3c
STM-1
Coax
BNC
12.7 dB*
CMI
75
T3
T3
Coax
BNC
150 m
B3ZS
75
E3
E3
Coax
BNC
150 m
HDB3
75
E1
E1
Coax (UTP)
BNC (RJ-45)
12 dB
HDB3
75 (120)
E1/LTU
E1
Coax (UTP)
BNC (RJ-45)
12 dB
HDB3
75 (120)
* At 78 MHZ, according to the square root of the frequency law.