beautypg.com

Chapter 4 software management – RAD Data comm ARC-101 User Manual

Page 35

background image

Accessing, Using and Exiting Monitor Mode

4-1

Chapter 4

Software Management

4.1 Introduction

Monitor mode enables software management of the ARC-101. Four
categories of software management are available:

Monitoring the ARC-101 general information via the General Information
window.

Changing default configuration parameters via the Configuration window.

Testing and resetting the ARC-101 via the Diagnostics window.

Monitoring the ARC-101 performance and status via the Performance
Monitoring window.

4.2 Accessing, Using and Exiting Monitor Mode

To Access Monitor
Mode

To access Monitor mode from the supervisory terminal, perform the
following:

Connect an ASCII ANSI terminal or a PC capable of emulating an ASCII
ANSI terminal to the RJ-45 CONTROL connector on the front panel of the
ARC-101. Terminal communication port setup should have a baud rate of
9600 bps, 8 bits/character, one stop bit, no parity.

If using a PC, run a terminal emulation program.

Make sure the ARC-101 is ON.

After a few seconds (during which the ARC-101 executes its self-test),
the main menu will be displayed on the screen.

ARC MENU

1. General Information
2. Configuration
3. Diagnostics
4. Performance Monitoring

ESC. Exit

Choose item from the menu:

To select an option, select the item number corresponding to the option.
If no change is required, press the Escape key (Esc).