Operating environment, Ruggedape™ specifications, 5 operating environment – RuggedCom RUGGEDBACKBONE RX1501 User Manual
Page 42: 6 ruggedape™ specifications, Sfp gigabit transceivers
Chapter 4
Technical Specifications
RuggedBackbone™ RX1501
Installation Guide
36
Operating Environment
Order
Code
Mode
Connector
Type
Cable
Type
(μm)
Tx λ
(typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
FG04
SM
SC
9/125
1310
-5
0
-20
-3
25
15
FG05
SM
LC
9/125
1310
-7
-3
-24
-3
25
17
SFP Gigabit Transceivers
Table 21: SFP Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable
Type
(μm)
Tx λ
(typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
50/125
0.5
FG51
MM
LC
62.5/125
850
-9
-2.5
-20
0
0.3
11
FG52
SM
LC
9/125
1310
-9.5
-3
-19
-3
10
9.5
FG53
SM
LC
9/125
1310
-7
-3
-23
-3
25
16
FG54
SM
LC
9/125
1550
0
5
-23
-3
70
23
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches
and splices. Please consult RuggedCom sales associates when determining maximum segment distances.
2. All optical power numbers are listed as dBm averages.
3. F51 transceivers are rated for -40°C to +85°C.
Section 4.5
Operating Environment
Table 22: Operating Environment
Parameter
Range
Comments
Ambient Operating Temperature
-40°C to 85°C
Ambient Temperature as measured from a 30cm
radius surrounding the center of the enclosure.
Section 4.6
RuggedAPE™ Specifications
Table 23: RuggedAPE™ Specifications
Feature
APE1402
APE1402W7
APE1404
APE1404W7
APE1404CPK
Processor
Intel Atom E660 1.3 GHz, 512KB L2 Cache
Intel Atom E660T 1.3 GHz, 512KB L2 Cache
RAM
2 GB DDR2, 800 MHz, 32-bit
Disk
8 GB SATA, solid state
16 GB SATA, solid state
Networking
Realtek RTL8111, RJ45 Gigabit Ethernet interface