Technical specifications, Power supply specifications, Critical alarm relay specifications – RuggedCom RUGGEDBACKBONE RX1501 User Manual
Page 39: 1 power supply specifications, 2 critical alarm relay specifications
RuggedBackbone™ RX1501
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications
33
Technical Specifications
Section 4.1
Power Supply Specifications
Table 15: Power Supply Specifications
Input Range
Power
Supply Type
Min
Max
Internal
Fuse Rating
Max. Power
Consumption
a
Max Power
Output
Connections
88 VDC
300 VDC
HI
85 VAC
264 VAC
2A(T)
b
65W Max
50W
Screw
terminal block
88 VDC
300 VDC
HIP
85 VAC
264 VAC
2A(T)
b
65W Max
50W
Pluggable
terminal block
24
10 VDC
36 VDC
2A(T)
b
52W Max
42W
Screw
terminal block
24P
10 VDC
36 VDC
2A(T)
b
52W Max
42W
Pluggable
terminal block
48
36 VDC
72 VDC
2A(T)
b
52W Max
42W
Screw
terminal block
48P
36 VDC
72 VDC
2A(T)
b
52W Max
42W
Pluggable
terminal block
a
Power consumption varies based on configuration.
b
(T) denotes time-delay fuse.
Section 4.2
Critical Alarm Relay Specifications
Table 16: Form C Contact Relay Specifications
Voltage
Current
30VDC
5A
250VAC
6.25A