P33-4 Zero Clearance Direct Vent Gas Fireplace

7

DUCT SYSTEM OPTION

kit #946-556

The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations
in the same room or other rooms in your
home.

Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.

INSTALLATION

CHECKLIST

1) Locate appliance
a)

Room

location

(Refer to "Locating Your Fireplace"
Section)

b) Clearances to Combustibles

(Refer to "Clearances" Section)

c)

Mantle

Clearances

(Refer to "Combustible Mantels"
Section)

d) Framing & Finishing Requirements

(Refer to "Framing & Finishing"
Section)

e)

Venting

Requirements

(Refer to "Venting" Sections)

2) Assemble Top Facing Support and Side

Nailing Strips (Refer to "Unit Assembly Prior
to Installation" Section). NOTE: Must be
done before installing unit into fi replace.

3) Install vent (Refer to "Venting" Sections)

4) Make gas and electrical connections. Test

the pilot. Must be as per diagram.

(Refer to "Gas Line Installation" and "Pilot
Adjustment" Section).

Convert to Propane if desired.

(Refer to "Conversion Kit from NG to LPG"
Section).

5) Install standard and optional features. Refer

to the following sections:

a. Optional Brick Panels

b. Log Set Installation

c.

Standard

Flush

Door

d.

Optional

Flush

Trim

e. Double Screen Door

f. Optional Bay Door

g.

Optional

Bay

Trim

h.

Flush

Louvers

i. Bay Louvers

j.

Full

Screen

Doors

k.

Optional

Wall

Themostat

l. Optional Remote Control

m. Optional Wall Switch

n. Installing the Optional Fan

6) Final

check.

Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained
to customer
.

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label) after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

Diagram 1

INSTALLATION

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

LOCATING YOUR

FIREPLACE

1) When selecting a location for your fi replace,

ensure that the clearances outlined on this
page are met.

2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r

servicing.

3) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.

UNIT DIMENSIONS

4) The P33-4 can be installed in a recessed

position or framed out into the room as in
A, B, C, D. See Diagram 1 below.

5) This appliance is Listed for bedroom

installations when used with a Listed
Millivolt Thermostat. Some areas may
have further requirements, check local
codes before installation.

6) The P33-4 Direct Vent Gas Fireplace

is approved for alcove installations,
which meet the clearances listed on the
"Clearances" Section.

7) We recommend that you plan your

installation on paper using exact
measurements for clearances and fl oor
protection before actually installing this
appliance. Have a qualifi ed inspector,
dealer, or installer review your plans before
installation.

Note: For vent terminations see "Exterior

Vent Termination Locations" Section.

A)

Flat on Wall

B)

Flat on Wall Corner

C) Recessed

into

Wall/Alcove