MAINTENANCE

THERMOPILE/

THERMOCOUPLE

1) Open the bottom louvers.

2) Loosen the thermocouple or thermopile with

a 7/16" wrench.

3) Disconnect thermocouple by loosening

nut from the valve with a 9mm wrench.
Disconnect thermopile by loosening 2
screws marked TP on the valve.

4) Drop the thermocouple or thermopile down

from the bracket and pull it out of the unit.

5) Reinstall the new ones in reverse order.

GLASS GASKET


If the glass gasket requires replacement use
5/8" fl at glass gasket for the Bay Front (Part
# 936-243) and a tadpole glass gasket for the
Flush Front (Part # 936-155).

DOOR GLASS

Your Regency

®

fi replace is supplied with high

temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency

®

dealer only, and follow our step-by-

step instructions for replacement.

Flush Glass Replacement

Remove the fl ush door front. Remove the 4
glass clips from each corner. Slide in the new
replacement glass. Push the 4 glass clips
back onto the frame. The glass must have
gasketing around it.

Bay Glass Replacement

1) Remove the door from the unit and place

on a soft surface to prevent scratching.

2) Remove the nuts holding the glass clips

in place and remove.

3) Replace the glass. The glass must have

gasketing around it.

5) Reverse the previous steps, replace the

glass clips and fasten with the nuts but
do not over tighten, as this can break the
glass.

6) Replace door on the Fireplace and check

the seal.

Caution: Wear gloves when removing
damaged or broken glass.

WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.