beautypg.com

1 troubleshooting until the emulator starts up, Chapter 5. troubleshooting – Renesas Compact Emulator M30620T-CPE User Manual

Page 40

background image

( 40 / 52 )

Chapter 5. Troubleshooting

5.1 Troubleshooting Until the Emulator Starts Up

Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated
until the emulator debugger starts up.

Figure 5.1 Flowchart to remedy the troubles

Troubleshooting until the emulator starts up

Emulator system started up normally

Result of checking

emulator function

Connection of

target

Self-checks start automatically
after powering on the emulator

Self-check sequence when the emulator starts up

Starting up

PD30M

Result of checking

emulator function

NMI* pin = H ?

BYTE pin = L ?

CNVss pin = L ?

RESET* pin = H ?

Self-checks terminated normally

Target status LED displays normally

Self-check error detected

Target status LED displays abnormally

No

Target power

turned ON ?

No

No

No

No

No

Error

Yes

Yes

Yes

Yes

Yes

RESET* control of

emulator possible?

Self-checks
terminated normally

Started up normally
Program Window displayed

Refer to "Troubleshooting When PD30M Starts Up"

Turning on the power of emulator

Self-checks executes

during about 7 seconds

after powering on the

emulator

Error detected in self-checks

Error detected

Connected

Disconnected

Yes

Normal

Refer to "Troubleshooting When the Emulator Starts Up"