beautypg.com

Rinnai RHFE-431WTA User Manual

Page 8

background image

– 6 –

Safety Devices

Noise Level Range

HI

LOW

38

32dB(A)

TYPE

SPECIFICATIONS FOR VENT SIZES

S

Thin Walls Mobile Home

Wood Walls

Wood/Brick

Brick/Block

Special

3"

4 1/2"

(75

115mm)

4 1/2"

9 1/2"

(115

240mm)

9 1/2"

15 3/4"

(240

400mm)

15 3/4"

23 5/8"

(400

600mm)

23 5/8"

31 1/2"

(600

800mm)

A

B

C

D

3 1/8" (80mm)

(4m, 2 bends)

13ft., 2 bends

Combustion Method

Air Supply Exhaust

Radiation Method

Forced combustion

Closed Type

Forced convection

Wall Penetration
Hole

AIR SUPPLY/
EXHAUST PIPE

Flame failure – Flame rod
Over heat – Bi-metal switch, thermal fuse, thermistor
Power failure – PCB
Power surge – 3 Amp. fuse
Fan delay – Micro computer timer
Pre-purge – Combustion fan, pre-purge timer, spark sensor
Room over heat – Automatic cut off at 104°F after 10 minutes

** BTU - Efficiency increases with vent Extension. Clearances from combustibles see pages 3 and 18.
** Thermal efficiency rating determined under continuous operating conditions, and was determined

independently of any installed system.

Max. Extended
Length