Rinnai RHFE-431WTA User Manual
Page 8
![background image](/manuals/196646/8/background.png)
– 6 –
Safety Devices
Noise Level Range
HI
LOW
38
32dB(A)
TYPE
SPECIFICATIONS FOR VENT SIZES
S
Thin Walls Mobile Home
Wood Walls
Wood/Brick
Brick/Block
Special
3"
4 1/2"
(75
115mm)
4 1/2"
9 1/2"
(115
240mm)
9 1/2"
15 3/4"
(240
400mm)
15 3/4"
23 5/8"
(400
600mm)
23 5/8"
31 1/2"
(600
800mm)
A
B
C
D
3 1/8" (80mm)
(4m, 2 bends)
13ft., 2 bends
Combustion Method
Air Supply Exhaust
Radiation Method
Forced combustion
Closed Type
Forced convection
Wall Penetration
Hole
AIR SUPPLY/
EXHAUST PIPE
Flame failure – Flame rod
Over heat – Bi-metal switch, thermal fuse, thermistor
Power failure – PCB
Power surge – 3 Amp. fuse
Fan delay – Micro computer timer
Pre-purge – Combustion fan, pre-purge timer, spark sensor
Room over heat – Automatic cut off at 104°F after 10 minutes
** BTU - Efficiency increases with vent Extension. Clearances from combustibles see pages 3 and 18.
** Thermal efficiency rating determined under continuous operating conditions, and was determined
independently of any installed system.
Max. Extended
Length