Maintenance and Troubleshooting

PlasmaWall SP Series Owner’s Operating Manual

51

PRE

L

IMINAR

Y

Image appears “washed out”
and/or dark areas appear too
bright.

• Brightness is set too high.

• Lower the brightness

setting.

Colors in the image are
swapped; for example, reds
appear blue or vice versa.

• The Red/Pr, Green/Y or

Blue/Pb outputs from the
source are connected to
the wrong inputs on the
DHD Controller.

• The Red, Green or Blue

(analog) outputs from the
DHD Controller are
connected to the wrong
inputs on the PlasmaWall.

• Ensure that the source

outputs are connected to
the correct DHD Controller
input.

• Ensure that the DHD

Controller outputs are
connected to the correct
inputs on the PlasmaWall.

RGB-HD images appear
“noisy.”

• Clock and Phase settings

need adjustment.

• Adjust Clock and Phase

settings (refer to ISF Night
- Display Color
on
page 43
).

“Out of range” appears
on-screen.

• The resolution and

frequency of the video
card in the computer are
not compatible with the
PlasmaWall.

• Select a compatible

resolution and vertical
frequency (refer to
Computer/Video Signal
Compatibility
on
page 64
).

The image is too large or too
small.

• Image size needs

adjusting.

• Adjust the image size (refer

to Input Position on
page 41
).

Table 5-1. Troubleshooting Chart (continued)