Installation, Installing the optional fan – Regency ULTRAGLOOW G36D-LP PROPANE User Manual
Page 31
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace
31
120 Volt AC power is needed for the fan switch
and blower. A three wire power cord is provided
to be plugged into the receptacle.
Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Open the bottom louver door.
3) Slide the fan in towards the rear of the unit
and slip it over the two mounting studs.
Ensure that the fan blades do not rub
against the valve tubing.
Optional:
If you require extra space to slide the fan to the back, the left spring can be unhooked
from the bracket.
Note: A 120 Volt AC power cord can be in-
stalled at rough-in stage so that the
power is available. A three wire power
cord can be used.
5) If the left spring was unhooked in step 3),
hook it back into the bracket. Take care not
to clip any wires. Attach the adhesive backed
wire holder clip (Part #910-199) onto the
stove base.
INSTALLATION
INSTALLING THE OPTIONAL FAN
4) Plug the fan to the receptacle as shown in
the wiring diagram below.
To Remove the Fan
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure
you vacuum the fan area on a regular
basis.