UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

18

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Required Parts:

Part #

Description

946-529 Co-linear

DV

Vertical

Termination

Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter

Kit

which contains the following:

Co-linear

Flex

Adapter

Outer

Pipe

Inner

Pipe

Adapter

510-994 Rigid

Pipe

Adaptor

Alternate Approved Caps
980 Vertical

Termination

Cap

991 High

Wind

Cap

923GK 3" Co-linear Adapter with fl ashing

Flex Liner

Exhaust

Flue

A maximum

of two certified

joiner kits

may be used

per length.

#948-305 (35 ft)

Air Intake

Co-linear DV

Vertical Termination

Cap # 946-529

Co-Linear

Flex

Adapter

with Kit#

946-563

Outer

Pipe

with Kit#

946-563

Inner Pipe

Adapter

with Kit#

946-563

Rigid Pipe Adaptor

# 510-994

90 Degree

Elbow

Pipe Length

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

FPI Cabinet and/or Flat Wall Mantles
may be used in these applications en-
suring that clearances to combustibles
are maintained.