RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

ULTRAGLOW DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90

o

elbow (two 45

o

elbows equal one 90

o

elbow).

Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems.

All Rigid Pipe Systems
4" inner diameter
6-5/8" outer diameter

UltraGlow Flex Vent
4" inner diameter
6-7/8" inner diameter

• Maintain clearances to combustibles as listed on pages 7 and 8.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.

A vent guard should be used when-
ever the termination is lower than
the specifi ed minimum or as per
local codes.

Note: UltraGlow Direct Vent System

(Flex) is only approved for hori-
zontal terminations.

INSTALLATION