Raypak RAYTHERM 0133-4001 User Manual
Page 4

4
CALIFORNIA PROPOSITION 65
WARNING:
This product contains chemicals known to the State
of California to cause cancer, birth defects or other
reproductive harm.
BOILER TYPES
TYPE H1 - MECHANICAL MODULATING
Central heating boiler with 150°-210°F
mechanical modulating gas valves and pressure relief
valve. Standard on models 133-1826.
TYPE H2 - MOTORIZED MODULATING
Central heating boiler with a motorized
modulating gas valve. Standard on models 2100-
4001. Available as option on models 514-1826.
Modulating controller provided.
TYPE H3 - 2-STAGE CONTROLS
Central heating boiler with single two-stage gas
valve . Available as option on Models 183-4001. Two-
stage controller provided. Available with Y-1
sequencing option.
TYPE H4 - ON-OFF CONTROLS
Central heating boiler with on-off firing. Available
as option on Models 181-4001.
TYPE H5 - MECHANICAL MODULATING
Central heating boiler with 110°-170°F
mechanical modulating gas valves and pressure relief
valve. Standard on Models 133-1826.
TYPE H6 - B6000 SYSTEM CONTROL
Central heating boiler for use with the B6000
boiler management system. Available for Models
514-4001.
TYPE H9 - 4-STAGE
Central heating boiler for use with 4-stage firing.
Controller optional. Available option on Models 514-
4001.
RECEIVING EQUIPMENT
On receipt of the equipment, visually check for
external damage to the carton or the shipping crate. If
either is damaged, make a note on the Bill of Lading
and report the damage to the Carrier immediately.
Remove the boiler from the carton or the shipping
crate.
On occasion, items are shipped loose. Be sure
that you receive the number of packages indicated on
the Bill of Lading.
When ordering parts, you must specify the Model
and Serial Number of the boiler. When ordering under
warranty conditions, you must also specify the date of
installation.
Raypak recommends that this manual be
reviewed thoroughly before installing your Raypak
boiler. If there are any questions which this manual
does not answer, please contact the factory or your
local Raypak representative.
Claims for shortages and damages must be filed
with carrier by consignee. Permission to return goods
must be factory authorized and are subject to a
stocking charge.
Purchased parts are subject to replacement only
under the manufacturer's warranty. Debits for
defective replacement parts will not be accepted and
will be replaced in kind only per our standard
warranties.
CERTIFICATIONS
The Raypak hydronic boilers are design certified
and tested under the latest requirements of the
American National Standard, ANSI Z21.13 - latest
edition. Each boiler has been constructed and
pressure tested in accordance with the requirements
of Setion IV of the American Society of Mechanical
Engineers Code, and factory fire tested.
All models are National Board approved.
Temperature and pressure gauge is standard.
Model 0133 has a 4-pass heat exchanger, 1 tube
per pass.
Models 0181-1826 have 2-pass heat exchangers,
5 tubes first pass, 4 tubes second pass.
Models 2100-4001 have 2-pass heat exchangers,
9 tubes per pass.
Models 926-4001 have optional single-pass heat
exchangers with cast iron headers only.