Tablec-4. extended at* command set, Table c-4, Table c – NETGEAR XM128 ISDN User Manual
Page 114

Reference Guide for the Model XM128 ISDN Digital Modem
C-12
AT Command Set Reference
lists the extended AT* command set.
Table C-4.
Extended AT* command set
Command
Options
Function and description
*Cn
n=0-3
Character length, including start, stop and parity bit. See also S-register 15.3 and
15.4. For a description of Extended S-registers, refer to Table D-4 on page D-5 in
Appendix D, “Status Registers and Result Codes."
*C0 *
10-bit character length.
*C1
11-bit character length.
*C2
9-bit character length.
*C3
8-bit character length.
*Dn
n=0-39
Sets default dial pointer at telephone directory location n. See also S-register 29.
For a description of Extended S-registers, refer to Table D-4 on page D-5 in
Appendix D, “Status Registers and Result Codes."
*D0 *
See also S35.4 and S38.0. For a description of Extended S-registers, refer to
Table D-4 on page D-5 in Appendix D, “Status Registers and Result Codes."
*Gn
Security function selection. See also S-registers 36.5 to 36.7. For a description of
Extended S-registers, refer to Table D-4 on page D-5 in Appendix D, “Status
Registers and Result Codes."
*G3
Enables type 2 security, with password check.
*G4
Enables type 2 security, with password check and callback.
*G5
Enables type 2 security, with password check and callback; remote site enters the
callback number.
*GCn
n=0-1
Callback function selection.
*GC0
Disables callback function.
*GC1
Enables callback function.
*HCn=s
n=0-4
Assigns callback phone number, s to storage location n.
*Hn
n=0-39
Modifies user password table at location n.
*HS
Modifies supervisory password (Default: NETGEAR).
*T
Recalls the last CND (Caller ID) information.
*V
Views the Password table.
*VC