Telnet interface-port 2005, Command summary – Network Technologies SM-8X4-HDA User Manual
Page 20

NTI AUDIO/HD VIDEO MATRIX SWITCH
16
Telnet Interface-Port 2005
For a software control type of telnet interface session (versus operator telnet control through port 2000 as described on page 14),
connect to the VEEMUX through the current IP address at port 2005. To do this, a connection to port 2005 must first be enabled
(see Web Setup on page 25). Then, with port 2005 enabled, use the command set below to control and acquire information from
the VEEMUX.
Legend: (All numbers must be two digits)
OP
:
Output Port (01-MAXOUTPUTS)
IP
:
Input Port (01-MAXINPUTS)
Carriage Return (Hex 0xD)
Command Summary
Command String
Good Response
Description
RU
ru OP,IP
Read unit size
RO OP
pc OP,IP
Read connection for OP
CS OP,IP
*
Connect OP to IP
CA IP
*
Connect all outputs to IP
SS 01
*
Enable auto-status mode
SS 00
*
Disable auto-status mode
SX
See details
Examine connections
AO OP
ac OP,IP
Read audio connection for OP
AS OP,IP
*
Connect audio OP to IP
AA IP
*
Connect all audio outputs to IP
AV OP,VV
*
Set audio volume for OP
AM OP,MM
*
Set audio mute status for OP
AR OP
ar OP:MM,VV
Read mute and volume for OP
XX
Close
connection
A
string will be inserted automatically to avoid buffer overflow. An eventual
ignored. A bad string will always be responded to with the ASCII character ‘?’ followed by a
Notes:
•
If Port 2005 connection is idle for 10 seconds it will disconnect
•
Up to 2 active connections are allowed at the same time
•
After establishing the connection, the unit will answer with *
connections established, it will answer with ?