beautypg.com

Telnet interface-port 2005, Command summary – Network Technologies SM-8X4-HDA User Manual

Page 20

background image

NTI AUDIO/HD VIDEO MATRIX SWITCH

16

Telnet Interface-Port 2005

For a software control type of telnet interface session (versus operator telnet control through port 2000 as described on page 14),
connect to the VEEMUX through the current IP address at port 2005. To do this, a connection to port 2005 must first be enabled
(see Web Setup on page 25). Then, with port 2005 enabled, use the command set below to control and acquire information from
the VEEMUX.


Legend
: (All numbers must be two digits)

OP

:

Output Port (01-MAXOUTPUTS)

IP

:

Input Port (01-MAXINPUTS)

:

Carriage Return (Hex 0xD)

Command Summary

Command String

Good Response

Description

RU

ru OP,IP

Read unit size

RO OP

pc OP,IP

Read connection for OP

CS OP,IP

*

Connect OP to IP

CA IP

*

Connect all outputs to IP

SS 01

*

Enable auto-status mode

SS 00

*

Disable auto-status mode

SX

See details

Examine connections

AO OP

ac OP,IP

Read audio connection for OP

AS OP,IP

*

Connect audio OP to IP

AA IP

*

Connect all audio outputs to IP

AV OP,VV

*

Set audio volume for OP

AM OP,MM

*

Set audio mute status for OP

AR OP

ar OP:MM,VV

Read mute and volume for OP

XX *

Close

connection


A (carriage return, 0x0D) is considered to be the end of the command string. If a string exceeds 16 characters, an end of
string will be inserted automatically to avoid buffer overflow. An eventual (line feed, new line, 0x0A) after a will be
ignored. A bad string will always be responded to with the ASCII character ‘?’ followed by a .

Notes:

If Port 2005 connection is idle for 10 seconds it will disconnect

Up to 2 active connections are allowed at the same time

After establishing the connection, the unit will answer with *. If the connection fails or there are already 2
connections established, it will answer with ?