Adjustments, Pilot burner adjustment, Venturi adjustment – Napoleon Fireplaces GD36PTR User Manual

Page 32: Flame adjustment, Flame characteristics

background image

32

W415-0210 / R / 02.27.08

These settings are for rear vented (maximum) horizontal
termination. Adjustment may be required depending on fuel
type, vent confi guration and altitude.
Closing the air shutter will cause a more yellow fl ame, but can
lead to carboning. Opening the air shutter will cause a more
blue fl ame, but can cause fl ame lifting from the burner ports.
The fl ame may not appear yellow immediately; allow 15 to 30
minutes for the fi nal fl ame colour to be established.

Air shutter adjustment must only be done by a

qualifi ed installer!

To access the air shutter, remove the two screws that secure
the cover to the air housing, taking care not to damage the
gasket.

FLAME MUST

ENVELOPE

UPPER 3/8" TO 1/2" OF

THERMOCOUPLE &

THERMOPILE

PILOT

BURNER

THERMOCOUPLE

THERMOPILE

Adjust the pilot screw to provide properly sized fl ame. Turn
in a clockwise direction to reduce the gas fl ow.

FIGURE 70

VENTURI

ORIFICE

AIR SHUTTER
OPENING

FIGURE 72

FIGURE 69

P

I

PI

PILOT SCREW

L OT

N O

L

OT

H I

L O

FF O

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

VENTURI

FIGURE 73

VENTURI ADJUSTMENT

GD36

BGD36

NG

1/16”

1/16”

LP

1/4”

1/4”

Both fi replace models have air shutters that have been factory
set open according to the chart below:

FLAME ADJUSTMENT

H I

LO

Turn counterclockwise

to decrease fl ame

height

Turn clockwise to

increase fl ame height

FLAME

ADJUSTMENT KNOB

FIGURE 71

FIGURE 74

FLAME CHARACTERISTICS

It is important to
periodically perform
a visual check of the
pilot and the burner
fl

ames. Compare

them to the fi gures
shown. If any fl ames
appear abnormal call
a service person.

3/8” - 1/2”

FIGURE 75

P

I

P ILOT

N O

L

O

T

H I

L O

FF O