Rear exit / horizontal termination – Napoleon Fireplaces GD36PTR User Manual

Page 12

background image

12

W415-0210 / R / 02.27.08

See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

For vent confi gurations requiring more than two 90° elbows
the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet

Example 4:

V

1

= 9 ft

V

2

= 6 ft

V

T

=

V

1

+

V

2

= 9 + 6 = 15 ft

H

1

=

3

ft

H

2

=

2

ft

H

3

=

1.5

ft

H

R

=

H

1

+

H

2

+

H

3

= 3 + 2 + 1.5 = 6.5 ft

H

O

= .03(four 90° elbows - 90°)

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

H

T

=

H

R

+

H

O

= 6.5 + 8.1 = 14.6 ft

H

T

+ V

T

= 14.6 + 15 = 29.6 ft

Formula 1:

H

T

< V

T

14.6 < 15

Formula 2:

H

T

+ V

T

< 40 feet

29.6 < 40

Since both formulas are met, this vent confi guration is
acceptable.

FIGURE 12

FIGURE 11

H

2

V

1

H

3

90°

90°

90°

90°

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

REAR EXIT / HORIZONTAL TERMINATION

H

1

V

2

Simple venting confi guration
(only two 90° elbows)

(H

T

) < (V

T

)

REQUIRED
VERTICAL
RISE IN
FEET

V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET

H

T

This manual is related to the following products: