CHAPTER 6 8-BIT TIMER/EVENT COUNTERS 00 AND 01

User’s Manual U12978EJ3V0UD

90

6.5 Notes on Using 8-Bit Timer/Event Counters 00 and 01

(1) Error on starting timer

An error of up to 1 clock occurs after the timer is started until a match signal is generated. This is because 8-bit

timer counters 00 and 01 (TM00 and TM01) are started asynchronously to the count pulse.

Figure 6-10. Start Timing of 8-Bit Timer Counter

Count pulse

TM00, TM01 count value

Timer starts

00H

01H

02H

03H

04H

(2) Setting of 8-bit compare register

8-bit compare registers 00 and 01 (CR00 and CR01) can be set to 00H.

Therefore, one pulse can be counted when the 8-bit timer/event counter operates as an event counter.

Figure 6-11. Timing of External Event Counter Operation

TI00, TI01 input

CR00, CR01

00H

TM00, TM01 count value

00H

00H

00H

00H

Interrupt request flag