beautypg.com

Nortel Networks 4500 Series User Manual

Page 38

background image

38

SFP specifications

The T1 equipment at the far end of the T1 connection must also use
an RJ-48C jack. After the pinout of the RJ-48C jack at the far end is
determined, determine if a straight-through or crossover cable is required.
An off-the-shelf straight-through cable can be used to directly connect the
T1 SFP module and the far-end T1 equipment if the far end has the pinout
shown in the following table.

Table 8
RJ-48C pinouts (opposite Tx and Rx connection)

Pin

Description

1

Transmit (Tx) ring

2

Transmit tip

3

Transmit shield

4

Receive (Rx) ring

5

Receive tip

6

Receive shield

7

Not used

8

Not used

If the far end connection does not match the connections shown in this
table (

Table 8 "RJ-48C pinouts (opposite Tx and Rx connection)" (page

38)

), then a crossover cable must be used. The crossover connections

are as shown in the following table.

Table 9
RJ-48C crossover cable connections

Terminal A

Terminal B

Pin

Description

Pin

Description

1

Receive ring

1

Transmit ring

2

Receive tip

2

Transmit tip

3

Receive shield

3

Transmit shield

4

Transmit ring

4

Receive ring

5

Transmit tip

5

Receive tip

6

Transmit shield

6

Receive shield

7

Not used

7

Not used

8

Not used

8

Not used

You can use a short crossover cable with a straight-through cable adapter
to connect to a straight-through cable. Do this to convert a straight-through
cable to a crossover cable.

Nortel Ethernet Routing Switch 4500 Series

Installation — SFPs and XFPs

NN47205-301

02.01

20 October 2008

Copyright © 2007-2008 Nortel Networks

.