Procedure steps, Cleaning duplex connectors, Prerequisites – Nortel Networks 4500 Series User Manual
Page 13
Care of fiber optic equipment
13
Procedure steps
Step
Action
1
Remove dust or debris by applying canned air to the cylindrical
and end-face surfaces of the connector.
2
Gently wipe the cylindrical and end-face surfaces with a tissue
dampened with optical-grade isopropyl alcohol.
3
Gently wipe the cylindrical and end-face surfaces with a dry
tissue.
ATTENTION
Do not let the IPA evaporate; wipe it dry immediately. Alcohols can
leave a residue that is difficult to remove.
4
Dry the connector surfaces by applying canned air.
5
Inspect the connector to ensure it is clean and undamaged.
To prevent contamination, do not touch the connector surfaces
after cleaning; and cover connectors with dust caps if you are not
going to use them right away.
--End--
Cleaning duplex connectors
Clean connectors so that the optical signal is minimally attenuated by the
connector.
This procedure is appropriate when more than dust contamination is
suspected.
Prerequisites
•
lens-grade, lint-free tissue (for example, Kimwipes)
•
optical-grade isopropyl alcohol (IPA) (98% or more pure)
•
high-quality canned compressed air with extension tube
Compressed air must be free of dust, water and oil, or filmy deposits or
scratches on the surface of the connector can result.
•
fiber optic microscope for inspecting connectors
Nortel Ethernet Routing Switch 4500 Series
Installation — SFPs and XFPs
NN47205-301
02.01
20 October 2008
Copyright © 2007-2008 Nortel Networks
.