May 2003
Installing the server and connecting the peripheral devices
Part 2: 702t Server Hardware Installation
47
4 Connect an RJ-45 network cable from the ELAN hub to the ELAN
connector on the server.
Note: The ELAN hub is optional if you use a cross-over network cable to
make a direct point-to-point connection from the server to the switch.
However, if you choose to establish a direct point-to-point ELAN
connection, no other device can connect to the ELAN.
5 At the switch, connect the ELAN network cable to an MAU (Ethernet)
transceiver. Then complete the connection from the transceiver to the
switch.
What’s next?
.
DANGER
Risk of fire hazard
MAU model NTRH9069 is not suitable for installation in
ducts, plenums, or other spaces used for environmental air. Do
not install it above a false ceiling or below a raised floor,
unless it can be confirmed that these spaces are not used to
convey environmental air.
IF the server will
THEN
be connected to a CLAN
continue with page 48.
not be connected to a CLAN
continue with installing the software
feature key adapter (dongle). See page
50.