beautypg.com

Technical data – Neumann.Berlin TLM 67 User Manual

Page 52

background image

5 2

Technical Data

Acoustical operating principle ........................... Pressure gradient transducer
Directional pattern ................................................................................................... Cardioid
Frequency range ..................................................................................... 20 Hz...20 kHz
Sensitivity at 1 kHz into 1 kohm .............................................................. 18 mV/Pa
Rated impedance ................................................................................................... 50 ohms
Rated load impedance .................................................................................. 1000 ohms
Signal-to-noise ratio, CCIR

1)

(rel. 94 dB SPL) .............................................. 73 dB

Signal-to-noise ratio, A-weighted

1)

(rel. 94 dB SPL) ................................ 84 dB

Equivalent noise level, CCIR

1)

................................................................................. 21 dB

Equivalent noise level, A-weighted

1)

............................................................ 10 dB-A

Maximum SPL for THD 0.5%

2)

...................................................................... 140 dB

Maximum output voltage .................................................................................... 13 dBu
Dynamic range of the microphone amplifier (A-weighted) ......... 130 dB
Supply voltage (P48, IEC 61938) ......................................................... 48 V ± 4 V
Current consumption (P48, IEC 61938) ........................................................ 3 mA
Matching connector .................................................................................................. XLR3F
Weight ................................................................................................................................. 480 g
Diameter ......................................................................................................................... 49 mm
Length ........................................................................................................................... 175 mm

®

Neumann is a registered trademark of the Georg Neumann GmbH in certain countries.

measured in free-field conditions (IEC 60268-4), tolerance ± 2 dB

1)

according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS

2)

measured as equivalent el. input signal