Error messages – Panasonic AJ-D92P User Manual
Page 55
55
Error Messages
Error code
Description
E — 68
This appears when there is a communication error between SERVO and AVSYS.
The data is fixed to High or Low.
Warning display
SLACK
E — 69
This appears when there is a problem in communication between SERVO and AVSYS
when the power is turned on.
SLACK
E — 6B
This appears when there is a communication error between IF and AVSYS.
There is a problem with the internal reference or external reference.
No display
E — 80
This appears when there is a problem with the supply voltage.
No display
E — 90
This appears when the backup battery has totally discharged.
No display
E — A0
This appears when there is no input of video signals or when video signals are cut off
and the mismatching detector circuit has been activated.
(The [E-A0] and the time data will be displayed alternately in the REC PAUSE mode.)
No display
E — bA
This appears when the input DC voltage has dropped to near the undercut voltage level
(approx. 10.6 V).
BATT flashes
E — 67
This appears when there is a communication error between SERVO and AVSYS.
There is a problem with the data.
SLACK
E — 65
This appears when abnormal tension has been detected.
SLACK
E — 66
This appears when the start or end processing operation fails to be completed within 7
seconds.