How to display the DIAG menu

Set the MENU switch to the ON position while
holding down the EJECT button.
The unit is set to the diagnosis display mode, and
“HOURS METER” appears on the video monitor.

1

Any item with “r” can be reset when servicing is
performed.

DIAG–MENU

HOURS METER

Ser
H00

OPERATION

00000H

H01

DRUM RUN

00000H

H02

TAPE RUN

00000H

H03

THREADING

00000T

H11

DRUM RUN r

00000H

H12

TAPE RUN r

00000H

H13

THREADING r

00000T

END

While the hours meters screen is displayed,
press the MENU-UP button or MENU-DOWN
button while holding down the PAGE button.
The software version is displayed on the video
monitor.

2

When the MENU-UP button or MENU-DOWN
button is pressed again while holding down the
PAGE button, operation returns to the hours
meter display.

DIAG–MENU

VERSION


IF

1.

-

- .

AV-SYSCON

1.

-

- .

DV

1.

-

- .

CYLINDER

1.

-

- .

REEL

1.

-

- .

END

Set the MENU switch to the OFF position.
Operation now returns to the normal mode.