10/100baset uplink (port 2), 10/100baset uplink (port 2) -4, Procedure – Paradyne IP DSLAM BitStorm 2600 User Manual

Page 26

background image

2. Cabling

2-4

March 2005

2600-A2-GN20-40

2. Connect the other end of the uplink cable to the uplink interface, such as an

Ethernet switch.

3. Port 3 (eth3) is the default uplink. If you have changed the default, use the

configure uplink CLI command or the Configuration / Uplink screen of the
web interface to specify eth3 as the uplink port.

10/100BaseT Uplink (Port 2)

Port 2 can be configured as the uplink for a single BitStorm 2600, or for the
terminating unit in a stack of BitStorm 2600s. A straight-through cable can be used
regardless of the destination interface, since the port automatically distinguishes
between an MDI and an MDIX.

Procedure

To use Port 2 as the uplink:

1. Connect an 8-position modular cable to Port 2.

2. Connect the other end of the cable to the uplink interface, such as an Ethernet

switch.

3. Using the configure uplink CLI command or the Configuration / Uplink

screen of the web interface, specify eth2 as the uplink port.

03-17441

SFP

Transceiver

LC

Connector

PORT1-10/100BT

CONSOLE

PORT2-10/100BT

PORT3

LINK

ACT

GigE

ST

ATUS

ALARM

TEST

ALARM

1000BT