6 Other
Displays:
Open probe detection is standard on all Pitco 
controls. If probe is detected open, normal 
heating and cooking activities are suspended. 
This display warns operators that the vat 
temperature has exceeded set temperature by 
+40°F (+22°C), or an absolute maximum of 
410°F (210°C). The alarm will also sound. This 
display does not show the status of the 
mechanical high limit switch. 
This message indicates that the drain valve has 
been opened, the vat is assumed to be empty by 
the controller. Normal heat control activities are 
suspended. Display will show an alternating 
message [DRAINING] / [TURN OFF]. To restore 
to normal operation, close the drain value. 
Display will show [TURN OFF]. 
Turn controller off, and refill the vat. Continue 
with normal operations at section 1. 
This message indicates that the heating system 
failed to respond. Typically, the high 
temperature limit switch has tripped and is in 
need of resetting. In the case on gas fired 
appliances, this message will display if the pilot 
fails to light or is detected marginal by the 
ignition module. Display will show an alternating 
message [HEAT] / [FAILURE]. 
This message indicates a shorted probe. If probe 
is detected as a short circuit, normal heating and 
cooking activities are suspended. Display will 
show an alternating message 
[SYSTEM] / [FAILURE]. 
This message indicates that a recoverable 
system error has occurred. Press ‘6’ for YES to 
perform a factory reset or ‘0’ for NO to return to 
OFF. Normal use of the system will only resume 
when a factory reset has been performed. 
Display will show an alternating message 
[FACTORY] / [RESET]. 