Pitco Frialator I12 Cooking Computer User Manual
Page 18

Spin Fryer I12 Cooking Computer 
Pitco P/N 60149505 
L22-355 Rev 1
Page 18 of 28
8
4.8.7 Factory
Reset
Factory Reset provides a quick way to erase all setup changes and restore control to 
factory settings. 
Warning: Any settings made prior to a factory reset will be lost. This includes 
customer specific downloads performed at Pitco Frialator. Heat profile after a reset 
is Generic 1 for gas appliances. 
With the display showing
, press 8 product key. After a few
moments, the display will show [ P ]. Press the
display will return to
.
4.8.8
Standing Pilot Toggle
For some applications, it is desirable to maintain the gas pilot flame when the appliance is 
OFF. Heat from the pilot keeps solid shortening in the liquid state for quicker warm-ups in the 
morning. Default setting for standing pilot is off. 
Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat. 
Standing Pilot toggle has no effect in with any other setting. 
With the display showing
, press product key 9. Display will
show [STANDING] [PILOT n], where “n” is ON or OFF. Use product key [0] change value, then
press the
to save choice. Display returns to
.
4.8.9 Set
Network
Address
With the display showing
, press key R.
Display will show [ADDR aa], where “aa” is a current address (default is 31) for this control. 
When controls are connected together for data collection, all controls must have different 
addresses for cooking computers that are tied together with the RS-485 communications 
port. 
To change this value, use the product keys for numeric entry of a new value.
Press the
key. Display returns to
.
4.9
To Exit Programming Level 3
With display showing
, press the
key.
Display will show
. Continue with changes in sections 2 or 3, or continue exit with
the next step. To return to normal operations, press the
key again.
R
