Pitco Frialator I12 Cooking Computer User Manual
Page 12
Spin Fryer I12 Cooking Computer
Pitco P/N 60149505
L22-355 Rev 1
Page 12 of 28
6
3.6
Recovery Test Value:
This controller maintains a record of heat up times for the appliance. A poorly running appliance
will have increased recovery times stored in this display. There is no selection done here, just the
display of recovery time values.
With display showing
, press the product key [0].
Display will show
.
Press product key 6; display will show [RECOVERY] [TEST].
Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery
value, and yyy is the last warm- up recovery value. Record these values for later comparison.