6

3.6

Recovery Test Value:

This controller maintains a record of heat up times for the appliance. A poorly running appliance
will have increased recovery times stored in this display. There is no selection done here, just the
display of recovery time values.

With display showing

, press the product key [0].

Display will show

.

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery
value, and yyy is the last warm- up recovery value. Record these values for later comparison.