Dsp memory capture, Dsp pcm capture, Dsp debugging events – Patton electronic 29XX User Manual
Page 147: Dsp connection performance, Failure to negotiate (dspfailurepercent)

DSP Connection Performance
147
Access Server Administrators’ Reference Guide
11 • Digital Signal Processing (DSP)
DSP Memory Capture
This portion of the DSP Settings window (see
) will store the memory content in 5 rotating circular
buffers. Each buffer contains the program and data memory associated with a call on the DSP. The buffer con-
tent is saved when the memory capture is triggered. Do not turn on unless requested by technical support.
DSP PCM Capture
This portion of the DSP Settings window (see
) captures the first 30 seconds of the pulse code modu-
lation on the incoming call on the specified DSP. Do not turn on unless requested by technical support.
DSP Debugging Events
Events for each call are automatically saved into a buffer. This buffer holds the last 100 DSP events for each
DSP. These are used for analysis by Patton Electronics.
DSP Connection Performance
This window (see
) shows connection summaries and statistics about the individual DSPs. Click on
Connection Summary…
on the DSP main window (see
on page 144) to display this window.
Figure 61. DSP Connection Performance window
Failure to Negotiate (dspFailurePercent)
Indicates the percentage of incoming calls that failed during modem negotiation.