Patton electronic 29XX User Manual
Page 126

Dial Out User Statistics Window
126
Access Server Administrators’ Reference Guide
8 • Dial Out
•
pppClose(8)—This reason will be given after PPP is initiated and the connection is disconnected. An exam-
ple would be if LCP negotiations failed.
•
lcpClose(9)—close initiated by LCP. This is a normal shutdown of a call.
•
loginTimeOut(10)—exceeded time limit to login.
•
userTerminated(11)—the TCP connection was terminated from the remote side.
•
maxNumCalls(21)—exceeds the maximum number of channels that can be allocated to the same call.
•
maxLoginAttempts(32)—exceeded maximum login attempts as defined under the dial-out link
•
noDspAvailable(45)—when the server tried to allocate a DSP for an outbound call but no available DSP’s
were available.
•
papAuthenticationFailure(49)—invalid username/password combination for tcp based calling.
•
exceedsMultiLinkLimit(64)—exceeds the maximum multilink calls set in the location table.
•
sessionTimeout(66)—the length of the connection exceeds the session time limit allowed.
•
noAnswer(85)—the remote modem did not answer the call.
•
userBusy(86)—the remote location is busy and did not answer the call
•
noChannelAvail(87)—no channels on the T1/E1 port were available to dialout with.
The following are internal access server errors. Please contact technical support if you see these termination rea-
sons on a consistent basis.
•
noPoll(12)
•
ipcPutMsgErr(13)
•
pollErr(15)
•
ioctlErr(16)
•
pppPutMsgErr(17)
•
dspIoctlErr(18)
•
timerErr(19)
•
pppOpenErr(22)
•
pppLinkErr(25)
•
tcpOpenErr(26)
•
tcpPushErr(27)
•
tcpPutMsgErr(28)
•
invalidPrim(29)
•
noTimers(33)
•
tcpLinkErr(34)
•
dspLinkErr(35)