beautypg.com

Paxar Monarch 9855 User Manual

Page 21

background image

17

704

Printer has not sensed a supply mark when expected or is out of
supplies. Press Escape/Clear and try to continue printing. Change
supply.

715

Invalid data length/data mismatch. The data in the RFID Data Field
has an incorrect data length or there is a data type mismatch between
selected data type and actual data entered. The printer accepts either 8
bytes (64-bit) or 12 bytes (96-bit) of data in the RFID Data Field. For
more information about the data length and data type, refer to your
RFIDMP Application Notes. Also, make sure you did not send 96-bit data
to a 64-bit RFID tag. Check with your System Administrator about your
format.

740

Command, hardware, inventory, or memory allocation error. There
may be an RFID hardware or memory allocation error.

741

RFID tag missing. Tag not found in RF Field. The RFID tag was not
found in the RF Field (area inside the printer where RFID tag is
programmed.) Check supply loading. If you made supply or print
position settings, make sure the RFID tag was not moved out of the
programmable range. See “About RFID Supplies,” for more information.

742

Tag erase failed. The RFID tag was found in the RF Field, but could not
be erased. Increase the number of retries. For more information, refer
to the RFIDMP Application Notes.

743

Program tag failed. The RFID tag was found in the RF Field, but could
not be programmed. Increase the number of retries. For more
information, refer to the RFIDMP Application Notes.

744

Tag locked fail. The RFID tag is unable to be programmed because it is
already locked. This is considered a bad RFID tag. For more
information, refer to the RFIDMP Application Notes.

746

Lock tag fail. The RFID tag has not been locked to prevent
reprogramming. This is considered a bad RFID tag. For more
information, refer to the RFIDMP Application Notes.

747

Time out failure. An RFID command (read, program, etc.) has failed to
complete in the maximum amount of allowed time.

748

Invalid data length/data mismatch from RFID interrogator module.
The RFID interrogator module found a problem with the data received
from the printer. For more information, refer to the RFIDMP Application
Notes
.

749

RFID Verify Fail. The RFID verification process failed after writing
(programming) tag. This is considered a bad RFID tag. For more
information, refer to the RFIDMP Application Notes.