beautypg.com

Patton electronic 1092ARC User Manual

Page 11

background image

To run or terminate a particular test, key in the option to get to that
screen menu.

Test Mode options 2,3,7,8 and 9 require the 1092ARC to be in Data

Mode with the remote 1092ARC. The Model 1092ARC Test Modes
are described below:

OFF

Terminates all tests

511

Initiates the built-in test pattern generator
and detector.

511 with Errors

Initiates the built-in test pattern generator
and detector. The test pattern generator
also injects intentional errors approximately
once per second.

Local Line Loop

Initiates the Local Line Loop test and starts

and 511

the internal 511 generator and detector.

Local Line Loop

Initiates the Local Line Loop test and starts

and 511 w/errors

the internal 511 generator and detector. In
this test, the 511 pattern generator injects
intentional errors into the data stream.

Remote Digital

Initiates the Remote Digital Loopback test.

Loop

Any data sent to the remote 1092 is
returned to the originating device.

Remote Digital

Initiates the Remote Digital Loopback test

Loop and 511

and starts the internal 511 generator and
detectors.

Remote Digital

Initiates the Remote Digital Loopback test

Loop and

and starts the 511test patterns. In this test

511 with errors

the 511 pattern generator will inject initial
errors into the data stream.

The Modem Status Screen is displayed upon initiating a test.

Press ‘ESC’ to return to the Test Mode Menu. Press the space bar to
refresh the modem status page.

20

MAIN MENU Option 6: Display Modem Status

Select Option 6 from

MAIN MENU

to display the Modem Status

(below). Press RETURN on the keyboard to update and redisplay the
screen.

Valid Model 1092ARC Handshake status conditions are listed
below:

1.

Handshaking - This status occurs when the 1092ARC is in
the process of establishing a link with another 1092ARC.

2.

Data Mode - This status occurs when the 1092ARC
successfully establishes a link with another 1092ARC allowing
the data to flow.

Press the space bar to refresh the modem status page.

MAIN MENU Option 7: Test Modes

Select Option 7 from the

MAIN MENU

to select the test mode status

of the Model 1092A. (below). The Model 1092A Test Mode settings
help to verify the integrity of the data link and isolate communication
difficulties.

19