Shown in the tables below are DIP Switch settings for Model 1080A.

Switches S1-5 and S1-6: Clock Source

Switches S1-5 and S1-6 are set in combination to determine the transmit
clock source for the Model 1080A Series.

Switch S1-7: Asynchronous/Synchronous Mode

The setting for switch S1-7 determines whether the Model 1080A Series
is in asynchronous or synchronous operating mode.

Table 2:

Model 1080A Data Rate Settings

S1-1

S1-2

S1-3

S1-4

Setting

On

On

On

On

1.2 kbps

Off

On

On

On

1.8 kbps

On

Off

On

On

2.4 kbps

Off

Off

On

On

3.6 kbps

On

On

Off

On

4.8 kbps

Off

On

Off

On

7.2 kbps

On

Off

Off

On

9.6 kbps

Off

Off

Off

On

14.4 kbps

On

On

On

Off

19.2 kbps

Off

On

On

Off

28.8 kbps

On

On

Off

Off

38.4 kbps

Off

On

Off

Off

57.6 kbps

S1-5

S1-6

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

S1-7

Setting

On

Asynchronous

Off

Synchronous