Switch S1-8: Carrier Control Method
The setting for switch S1-8 determines whether the carrier is “constantly
on” or “controlled by RTS”. This setting allows for operation in switched
carrier, multipoint and/or hardware handshaking applications.
3.3 CONFIGURATION SWITCH SET “S2”
The DIP switches on S2 set word length, extended signaling rate,
RTS/CTS delay, V.52 and V.54 diagnostic test and 2- and 4-wire opera-
tion.
Table 3:
S2 Summary
S1-8
Setting
Off
Constantly on
On
Controlled by RTS
Position
Function
Factory Default
S2-1
Word Length
Off
S2-2
Word Length
Off
S2-3
Extended Signaling Rate
Off -2.5% to 1%
S2-4
RTS/CTS Delay
On
S2-5
RTS/CTS Delay
On
S2-6
V.52/V.54 Tests
Off Normal Operation
S2-7
2-Wire/4-Wire
Off
(4-Wire)
S2-8
Not Used
N/A
}
}
7 ms
10 bits