13
setting, while a thinner gauge cable should receive a higher ohm setting.
If you are using higher speeds you will need a lower ohm setting, and a
higher ohm setting for the slower speeds. Refer to Table 5 for assistance
in selecting a setting.
Table 5:
S3-1, S3-2 Selection Table for Model 1080A
Switch S3-4: Mode Selection
The setting for switch S3-4 allows the user to choose the appropriate set-
ting for point-to-point or multipoint applications.
Switch S3-5: RS-232 Initiation of Local Loopback Test
The setting for switch S3-5 determines whether or not the Model 1080A
Series’ local analog loopback test can be initiated by raising pin 18 on
the RS-232 interface.
S3-1
S3-2
Setting
On
On
130 ohms
On
Off
200 ohms
Off
On
320 ohms
Off
Off
High impedance (minimum 2k¾)
S3-4
Setting
On
Point-to-point
On
Multipoint application as “Master”
Off
Multipoint application as “Slave”
S3-5
Setting
On
RS-232 initiation enabled
Off
RS-232 initiation disabled
Gauge of
Cable
19AWG/.9mm
22AWG/.6mm
24AWG/.5mm
26AWG/.4mm
1.2
320
320
320
320
Data Rates, kb/s
1.8
320
320
320
320
2.4
200
320
320
320
3.6
200
200
320
320
4.8
200
200
200
320
7.2
200
200
200
200
9.6
200
200
200
200
14.4
130
200
200
200
19.2
130
130
200
200
28.8
130
130
130
200
38.4
130
130
130
130
57.6
130
130
130
130