Each Model 1080A Series SRM has three sets of eight switches, yielding
24 total DIP switches. The three sets will be referred to as S1, S2 and
S3. As Figure 2 shows, the orientation of all DIP switches is the same
with respect to “ON” and “OFF” positions.

Figure 2.

Close-up of DIP switches showing “ON” and “OFF” positions

3.2 CONFIGURATION SWITCH SET “S1”

The DIP switches on S1 set data rate, clock source, async./sync. mode
and carrier control method. The default settings are summarized in
Table 1.

Table 1:

Model 1080A S1 Summary

Switches S1-1 through S1-4: Data Rate Setting

Switches S1-1 through S1-4 are set in combination to determine the
asynchronous and synchronous data rate for the Model 1080A.

OFF

ON

1

2

3

4

5

6

7

8

ON

Position

Function

Factory Default

S1-1

Data Rate

On

S1-2

Data Rate

Off

S1-3

Data Rate

Off

S1-4

Data Rate

On

S1-5

Clock Source

On

S1-6

Clock Source

On

S1-7

Async./Sync.

On

Async.

S1-8

Carrier Control

Off

Constantly On

9,600 bps

(

1080A

)

or

16,000 bps

(

1080A-64

)

Internal

}

}