Chapter 3: Starting Your PowerStation
PowerStation Connectors
PA PowerStation User Guide
3-4
Once you make a cable for communicating with COM2, you will need to set
the COM2 DIP switch settings.
COM2 is set to the RS-485 protocol by default. To change COM2 to the RS-
232 or RS-422 protocol, you must change the COM2 DIP switch settings.
The DIP switch for COM2 is located on the side of the PA PowerStation, as
shown in Figure 3-1 for the 5”, 6”, 8”, and 10” units.
Figure 3-1:
COM2 Dip Switch Settings for 5”, 6”, 8”, and 10” Units
•
The white boxes represent the tip of the switch.
•
The upper half of the switch is the ON position, and the lower half of the
switch is the OFF position.
To change the DIP switch settings, complete the following steps:
1
Choose the appropriate DIP switch settings from the diagram
displayed on the side of the PA PowerStation and the chart below.
Figure 3-2: DIP Switch on 5”, 6”, 8” and 10” Units
2
Using a pointed instrument such as a pen or pencil, flip the switches
to the appropriate settings through the viewing window.
Figure 3-3, displays the connector pinouts and cable wiring required for
communicating with COM1 or COM2 using the RS-232, RS-422 or the RS-
485 protocol. This figure is for the 5”, 6”, 8”, and 10” units only.