beautypg.com

Settings for basic mode, Setting the option straps, To change the mode of operation, see the – Paradyne COMSPHERE 3600 Series User Manual

Page 22: Setting the, Option straps, Section, Change the mode of operation, see the, Setting the option, Straps, Section.)

background image

COMSPHERE –48 Vdc Central Office Power Unit

2-6

May 1998

3000-A2-GB41-40

Setting the Option Straps

The option straps are screw switches that are set by

raising (loosening) or lowering (tightening) the screw to
break or make the contact. There are five option straps, S1
through S5, on the CO Power Unit’s backplane (see

Figure 2-2

).

NOTE

Older power modules have
straps labeled S1 and S2. These
should always be in the raised
position.

Basic Mode

If you want to operate in the Basic mode, you must use

one – 48 Vdc power source and configure the option straps
as shown in

Table 2-2

.

Table 2-2

Settings for Basic Mode

S1 Lowered

S2 Lowered

S3 Lowered

S4 Lowered

S5 Lowered

To set the option straps for Basic mode of operation:

"

Procedure

1. Tighten the screws on all five straps (S1 through

S5) on the CO Power Unit’s backplane. Make sure
that the screws are securely touching the contacts,
but do not screw the straps too tight because doing
so can damage the equipment.

S1

S2

S3

S4

S5

CO Power Tray

496-13695-01

CO Power Unit

Backplane

Figure 2-2. Option Straps (S1 through S5) on the CO Power Unit’s Backplane