beautypg.com

Troubleshooting • 6, Barcode problems (continued) other problems – Pitney Bowes ADDRESSRIGHT DA550 User Manual

Page 79

background image

Pitney Bowes DA500/DA550 Operator Guide

6-7

Troubleshooting • 6

Problem

Address too High

Reason:

Address field is within 1/10" of the top edge
of the media.

Solution:

Move address field down to within DMM
specifications.

Problem

Paper Out or Paper Jam

Reason:

Input area is empty.

Solution:

Refill the input area.

Reason:

H-Block separators not adjusted correctly.

Solution:

Adjust the H-Blocks to the thickness of the
material you're running. See page 3-7.

Reason:

Paper jam obstructing paper path.

Solution:

Clear obstructed path.

Reason:

Dirty paper feed sensor.

Solution:

Clean sensor with compressed air. See page
5-3.

Problem

Shuttle Jam

Reason:

Envelope thickness lever is set too low for
material.

Solution:

Open the transport door and adjust the media
thickness lever. See page 3-15.

Reason:

Lower rail shaft dirty.

Solution:

Wipe lower rail shaft clean.

Barcode
Problems
(continued)

Other
Problems

This manual is related to the following products: