User Guide V

2

IU 4300T Converged Network Appliance

3 - 48

1.

Log into the V

2

IU appliance using a Netscape or Internet Explorer web

browser.

2.

Select System.

3.

Select Survivability.

4.

Enter the desired values for Time between heartbeat messages, Time to

declare heartbeat lost, Number of lost messages to declare alarm and

Number of received messages to clear alarm in the Softswitch

Reachability section of the web page.

5.

Press Submit.

The reachability settings are used to determine when the V

2

IU appliance

provides local call switching by entering fallback mode and when it returns

call control to network based call processing servers. The definitions of the

reachability settings are as follows:
Time between heartbeat messages - The number of seconds between each

heartbeat message sent to the call processing servers to determine

connectivity.
Time to declare heartbeat lost – The number of seconds that the V

2

IU appliance

will wait before declaring a response to a heartbeat message lost.
Number of lost messages to declare alarm - the number of consecutively lost

responses to heartbeat messages required for the V

2

IU appliance to declare a

loss of connectivity to the network based call processing server.
Number of received messages to clear alarm - the number of consecutively

received responses to heartbeat messages required for the V

2

IU Appliance to

declare successful connectivity to the network based call processing server.
The formula used to determine the maximum time for the V

2

IU appliance to

declare a loss of connectivity to a call processing server is: maximum time =

(X * Y) + Z, where,
X = Time between heartbeat messages
Y = Number of lost messages to declare alarm
Z = Time to declare a heartbeat lost
The default value for X, Y and Z in the V

2

IU appliance is 5. Therefore, the

default maximum time to declare a call processing server unreachable is 30

seconds or ((5*5) + 5).

Step 3 - Specify the number of digits to use for local dialing

This field is the number of digits that the V

2

IU appliance will use for dialing

when providing local call switching. By default the V

2

IU appliance will use 4,

7 and 10 digit dialing. Please follow the steps below if you would like to use a

different number of digits:

1.

Log into the V

2

IU appliance using a Netscape or Internet Explorer web

browser.