DUTY CYCLE

This air compressor pump is capable of running continuously. However, to prolong

the life of your air compressor, it is recommended that a 50%-75% average duty

cycle be maintained; that is, the air compressor pump should not run more than

30-45 minutes in any given hour.

ASSEMBLY

UNPACkING

1. Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT
LOCATION OF THE AIR COMPRESSOR

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" (30.5 cm) away from the

wall or other obstructions that will interfere with the flow of air.

Place the air compressor on a flat level surface in the vertical position resting

on the rubber bumpers and wheels

The air compressor pump and shroud are designed to allow for proper cool-

ing. The ventilation openings on the compressor are necessary to maintain

proper operating temperature. Do not place rags or other containers on or

near these openings.

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the event of a short circuit, ground-

ing reduces the risk of shock by providing an escape wire for the electric cur-

rent. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with

an appropriate grounding plug (see following illustrations).
1. The cord set and plug with this unit contains a grounding pin. This plug

MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance

with all local codes and ordinances.
2. Make sure the outlet being used has

Grounding Pin

Grounded

Outlets

Plug

the same configuration as the ground-

ed plug.

DO NOT USE AN ADAPTER.

See illustration.

3. Inspect the plug and cord before

each use. Do not use if there are

signs of damage.

4. If these grounding instructions are

not completely understood, or if in doubt as to whether the compressor is

properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical Shock. IMPROPER GROUNDING CAN

RESULT IN ELECTRICAL SHOCk.
Do not modify the plug provided. If it does not fit the available outlet, a correct

outlet should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified electrician.